7 research outputs found

    Validation of an electrogoniometry system as a measure of knee kinematics during activities of daily living

    Get PDF
    Purpose: The increasing use of electrogoniometry (ELG) in clinical research requires the validation of different instrumentation. The purpose of this investigation was to examine the concurrent validity of an ELG system during activities of daily living. Methods: Ten asymptomatic participants gave informed consent to participate. A Biometrics SG150 electrogoniometer was directly compared to a 12 camera three dimensional motion analysis system during walking, stair ascent, stair descent, sit to stand, and stand to sit activities for the measurement of the right knee angle. Analysis of validity was undertaken by linear regression. Standard error of estimate (SEE), standardised SEE (SSEE), and Pearson’s correlation coefficient r were computed for paired trials between systems for each functional activity. Results: The 95% confidence interval of SEE was reasonable between systems across walking (LCI = 2.43 °; UCI = 2.91 °), stair ascent (LCI = 2.09 °; UCI = 2.42 °), stair descent (LCI = 1.79 °; UCI = 2.10 °), sit to stand (LCI = 1.22 °; UCI = 1.41 °), and stand to sit (LCI = 1.17 °; UCI = 1.34 °). Pearson’s correlation coefficient r across walking (LCI = 0.983; UCI = 0.990), stair ascent (LCI = 0.995; UCI = 0.997), stair descent (LCI = 0.995; UCI = 0.997), sit to stand (LCI = 0.998; UCI = 0.999), and stand to sit (LCI = 0.996; UCI = 0.997) was indicative of a strong linear relationship between systems. Conclusion: ELG is a valid method of measuring the knee angle during activities representative of daily living. The range is within that suggested to be acceptable for the clinical evaluation of patients with musculoskeletal conditions

    Gait analysis of fixed bearing and mobile bearing total knee prostheses during walking: Do mobile bearings offer functional advantages?

    Get PDF
    Background - Limited previous findings have detailed biomechanical advantages following implantation with mobile bearing (MB) prostheses after total knee replacement (TKR) surgery during walking. The aim of this study was to compare three dimensional spatiotemporal, kinematic, and kinetic parameters during walking to examine whether MBs offer functional advantages over fixed bearing (FB) designs. Methods - Sixteen patients undergoing primary unilateral TKR surgery were randomised to receive either a FB (n = 8) or MB (n = 8) total knee prosthesis. Eight age and gender matched controls underwent the same protocol on one occasion. A 12 camera Vicon system integrated with four force plates was used. Patients were tested pre-surgery and nine months post-surgery. Results - No significant differences between FB and MB groups were found at any time point in the spatiotemporal parameters. The MB group was found to have a significantly reduced frontal plane knee range of motion (ROM) at pre-surgery than the FB group (FB = 14.92 ± 4.02°; MB = 8.87 ± 4.82°), with the difference not observed post-surgery. No further significant kinematic or kinetic differences were observed between FB and MB groups. Fixed bearing and MB groups both displayed spatiotemporal, kinematic, and kinetic differences when compared to controls. Fixed bearing and MB groups differed from controls in six and five parameters at nine months post-surgery, respectively. Conclusions - No functional advantages were found in knees implanted with MB prostheses during walking, with both groups indicative of similar differences when compared to normal knee biomechanics following prosthesis implantation

    Classic Papers in Orthopaedics

    No full text
    XX, 624 p. 20 illus., 2 illus. in color.online re

    The rate of COVID-19 and associated mortality after elective hip and knee arthroplasty prior to cessation of elective services in UK

    No full text
    AIMS: The primary aim was to assess the rate of postoperative COVID-19 following hip and knee arthroplasty performed in March 2020 in the UK. The secondary aims were to assess whether there were clinical factors associated with COVID-19 status, the mortality rate of patients with COVID-19, and the rate of potential COVID-19 in patients not presenting to healthcare services.METHODS: A multicentre retrospective study was conducted of patients undergoing hip or knee arthroplasty during the first wave of the COVID-19 pandemic (1 March 2020 to 31 March 2020) with a minimum of 60 days follow-up. Patient demographics, American Society of Anesthesiologists grade, procedure type, primary or revision, length of stay (LOS), COVID-19 test status, and postoperative mortality were recorded. A subgroup of patients (n = 211) who had not presented to healthcare services after discharge were contacted and questioned as to whether they had symptoms of COVID-19.RESULTS: Five (0.5%) of 1,073 patients who underwent hip or knee arthroplasty tested positive for SARS-CoV-2 postoperatively. When adjusting for confounding factors, increasing LOS (p = 0.022) was the only significant factor associated with developing COVID-19 following surgery and a stay greater than three days was a reliable predictor with an area under the curve of 81% (p = 0.018). There were three (0.3%) deaths in the study cohort and the overall mortality rate attributable to COVID-19 was 0.09% (n = 1/1,073), with one (20%) of the five patients with COVID-19 dying postoperatively. Of the 211 patients contacted, two had symptoms within two to 14 days postoperatively with a positive predictive value of 31% and it was therefore estimated that one patient may have had undiagnosed COVID-19.CONCLUSION: The rate of postoperative COVID-19 was 0.5% and may have been as high as 1% when accounting for those patients not presenting to healthcare services, which was similar to the estimated population prevalence during the study period. The overall mortality rate secondary to COVID-19 was low (0.09%), however the mortality rate for those patients developing COVID-19 was 20%.</p

    Mapping analysis to predict the associated EuroQol five-dimension three-level utility values from the Oxford Knee Score: a prediction and validation study

    No full text
    Aims: The aims of this study were to assess mapping models to predict the three-level version of EuroQoL five-dimension utility index (EQ-5D-3L) from the Oxford Knee Score (OKS) and validate these before and after total knee arthroplasty (TKA). Methods: A retrospective cohort of 5,857 patients was used to create the prediction models, and a second cohort of 721 patients from a different centre was used to validate the models, all of whom underwent TKA. Patient characteristics, BMI, OKS, and EQ-5D-3L were collected preoperatively and one year postoperatively. Generalized linear regression was used to formulate the prediction models. Results: There were significant correlations between the OKS and EQ-5D-3L preoperatively (r = 0.68; p 0.090) in the validation cohort. There was a significant correlation between the actual and predicted EQ-5D-3L utilities preoperatively (r = 0.63; p < 0.001) and postoperatively (r = 0.77; p < 0.001) and for the change in the scores (r = 0.56; p < 0.001). Bland-Altman plots demonstrated that a lower utility was overestimated, and higher utility was underestimated. The individual predicted EQ-5D-3L that was within ± 0.05 and ± 0.010 (minimal clinically important difference (MCID)) of the actual EQ-5D-3L varied between 13% to 35% and 26% to 64%, respectively, according to timepoint assessed and change in the scores, but was not significantly different between the modelling and validation cohorts (p ≥ 0.148). Conclusion: The OKS can be used to estimate EQ-5D-3L. Predicted individual patient utility error beyond the MCID varied from one-third to two-thirds depending on timepoint assessed, but the mean for a cohort did not differ and could be employed for this purpose. Cite this article: Bone Jt Open 2022;3(7):573–581
    corecore